HSL LinkMaster Utility 71
4.2.4 HSL-DI16DO16 Utility
1. Slave Address. Shows the slave index occupied by the
module.
2. Digital Input. A white circle indicates no digital input; a
red icon indicates that the digital input is not activated.
3. Digital Output. Click on the icon to activate the digital
output. Red icon indicates that the digital output is turned
on, and vice-versa.
4. Slave Status: Shows the communication status between
the slave module and the master card. The functions
definition are enumerated below.
Z Bit 0 is Data_Req bit.
Z Bit 2 is for CHK1. When Bit2 is equal to 1, a communica-
tion error occurred once).
Z Bit 3 is for CHK3. When Bit3 is equal to 1, a communica-
tion error occurred three times.
Z Bit 4, Bit 5 and Bit 6 bits are for CHK7. WhenBit4, Bit5,
and Bit6 are all equal to 1, a communication error
occurred seven times.